Main Incoming Fuses are
manufactured by leading firms within the United States. These
fuses, and many cases are stocked for immediate delivery.
From left to right: Cooper
NX current limiting fuse, Ferraz Shawmut current limiting fuse,
and S&C non-current limiting fuse.
|
|
Main
Incoming Fuses
Compartment
|
NEPSI's Metal-Enclosed
Capacitor Banks and Harmonic Filter Banks are
equipped with a main-incoming fuse compartment
that is isolated from the capacitor/reactor compartment
and the main
incoming/air-disconnect compartment. This
allows for safe replacement of blown fuses. Fuses
are equipped with blown fuse indicators and are
visible through a window.
NEPSI tyically utilizes medium voltage current
limiting fuses from either Cooper Power Systems
or Ferras Shawmut. Non-Current Limiting Fuses
from S&C are also utilized for system voltages
greater than 15.5kV and when bank currents exceed
available current limiting fuse ratings. The specific
fuse utilized is dependent upon customer preference,
lead-time, cost, voltage and current rating.
|

Main
incoming fuses provide main bus protection for
the Metal-Enclosed Capacitor Bank or Harmonic
Filter Bank and provide backup protection for
capacitor fuses.
|
It should be noted that the main incoming fuses
are not intended for overload protection.
Specification
-
Voltage Rating -
Fuse voltage rating is chosen such that it
is greater than the system line-line voltage.
See Table-1 for available voltage ratings.
-
Current Rating -
Fuse current rating is chosen such that it
is at least 35% greater than the banks full
load current. Banks with expansion capability
may be equipped with higher current rated
fuses or with provision that will accept a
higher current rated fuse. See Table-1 for
available current ratings.
- Short Circuit Rating
- Fus short circuit rating is chosen such that
it is greater than the available short circuit
current at the capacitor bank terminals. See
Table-1 for maximum available values.
|
Table
1 - Available
Current Rating Range, Short Circuit
Ratings, and Product Literature
|
|
Fuse
Voltage Rating
(kV)
|
|
|
|
|
4.3
|
N/A
|
50kA,
18 - 100
|
N/A
|
|
5.5
|
63kA,
10E - 900E
|
50kA,
6 - 75
|
27kA,
To 720E #
|
|
8.3
|
N/A
|
50kA,
1.5 100
|
N/A
|
|
15.5
|
50kA,
10E - 300E
|
50kA,
1.5 - 100
|
N/A
|
|
17
|
N/A
|
N/A
|
25kA,
To 720E #
|
|
23
|
N/A
|
50kA,
6 - 40
|
N/A
|
|
27
|
N/A
|
35kA,
6 - 50
|
20kA,
To 300E #
|
|
38
|
N/A
|
35kA,
6 -50
|
17.5kA,
To 300E #
|
Adobe
Acrobat Files |
CL-14
Fuse Literature |
NX
Fuses Literature
X-Limiter
Literature
|
|
|
#
- Values shown are maximum values.
Depending upon fuse part number, ratings
may be less. See data sheets for detailed
data.
|
|