Main Incoming Fuses are manufactured by leading firms within the United States. These fuses, and many cases are stocked for immediate delivery.

From left to right: Cooper NX current limiting fuse, Ferraz Shawmut current limiting fuse, and S&C non-current limiting fuse.

 

 


Main Incoming Fuses
Compartment

NEPSI's Metal-Enclosed Capacitor Banks and Harmonic Filter Banks are equipped with a main-incoming fuse compartment that is isolated from the capacitor/reactor compartment and the main incoming/air-disconnect compartment. This allows for safe replacement of blown fuses. Fuses are equipped with blown fuse indicators and are visible through a window.

NEPSI tyically utilizes medium voltage current limiting fuses from either Cooper Power Systems or Ferras Shawmut. Non-Current Limiting Fuses from S&C are also utilized for system voltages greater than 15.5kV and when bank currents exceed available current limiting fuse ratings. The specific fuse utilized is dependent upon customer preference, lead-time, cost, voltage and current rating.


Main incoming fuses provide main bus protection for the Metal-Enclosed Capacitor Bank or Harmonic Filter Bank and provide backup protection for capacitor fuses.


It should be noted that the main incoming fuses are not intended for overload protection.


Specification

  • Voltage Rating - Fuse voltage rating is chosen such that it is greater than the system line-line voltage. See Table-1 for available voltage ratings.

  • Current Rating - Fuse current rating is chosen such that it is at least 35% greater than the banks full load current. Banks with expansion capability may be equipped with higher current rated fuses or with provision that will accept a higher current rated fuse. See Table-1 for available current ratings.

  • Short Circuit Rating - Fus short circuit rating is chosen such that it is greater than the available short circuit current at the capacitor bank terminals. See Table-1 for maximum available values.


    Table 1 - Available Current Rating Range, Short Circuit
    Ratings, and Product Literature
    Fuse Voltage Rating
    (kV)
    4.3
    N/A
    50kA, 18 - 100
    N/A
    5.5
    63kA, 10E - 900E
    50kA, 6 - 75
    27kA, To 720E #
    8.3
    N/A
    50kA, 1.5 100
    N/A
    15.5
    50kA, 10E - 300E
    50kA, 1.5 - 100
    N/A
    17
    N/A
    N/A
    25kA, To 720E #
    23
    N/A
    50kA, 6 - 40
    N/A
    27
    N/A
    35kA, 6 - 50
    20kA, To 300E #
    38
    N/A
    35kA, 6 -50
    17.5kA, To 300E #
    Adobe Acrobat Files CL-14 Fuse Literature

    NX Fuses Literature
    X-Limiter Literature

    # - Values shown are maximum values. Depending upon fuse part number, ratings may be less. See data sheets for detailed data.